York It's Time to Get Comfortable
McAfee Secure sites help keep you safe from identity theft, credit card fraud, spyware, spam, viruses and online scams
Text Size: A A A A A To Find Your Nearest York Dealer:
130 Years Design Innovation Comfort
About Us | Site Map Click on the button below:
Dealers/Distributors
When a project calls for quality, high-efficiency light commercial heating and cooling, look to York for innovative, cost-effective systems.
Dealers/Distributors
  Light Commercial
ArrowPackaged Heating & Cooling
ArrowPackaged Heat Pumps
ArrowSplit System Air Conditioners
ArrowSplit System Heat Pumps
ArrowIndoor Package Units - Air Cooled
ArrowIndoor Package Units - Water Cooled
rule
Homeowners
Engineers
Engineers
Business to Business
Printable Version

Meridian Control

Tonnage Capacities


Efficiency


Warranty
Other parts - 3/1 Yr(s)


Meridian Control System
With the York Meridian™ Control System, building owners and operators can network single-zone, constant-volume HVAC units, multiple-zoned units, or have a combination of both. Unlike complex and expensive building automation systems (BAS), Meridian was designed specifically for commercial unitary rooftop and split-system HVAC systems. Meridian application-specific unit controllers provide stand-alone functionality in a microprocessor-based device providing internal time-clock functions for 7/365 programming capability, holiday scheduling, and automatic daylight savings time adjustment.
Click Here for information on Meridian View software.

Special Benefits
  • Maintains backward compatibility with existing York EZ Zone Systems by providing a simple and cost-effective upgrade path.
  • Comprehensive, contractor-friendly documentation makes installation simple, allowing most technicians to install and startup the system without specialized training.
  • Simple start-up procedure eliminates most commissioning headaches.
  • Meridian Control System is non-proprietary, meaning it will work on any manufacturer’s HVAC equipment that has a standard thermostat connection.
  • Menu-driven system manager interface allows operator to program and monitor all standard controllers from one central location.
  • Flush-mount temperature sensors feature tamper-resistant design, and setpoint adjust range can be programmed for each controller.
  • CommLink II interface is standard on most systems and provides PC and modem connections for both on-site and remote monitoring.
  • Factory insulated commercial grade zone dampers come with heavy-duty Belimo actuators with real-time feedback and manual clutch override. Rectangular dampers are also available.
  • ZoneView software is a Windows-based program that includes trendlogging, status screens, and graphics.
  • Open-protocol platform allows other manufacturer products to integrate with the Meridian Control System.
  • 3 year electronics warranty on system components. 1 year on rectangular and round dampers. (Zone dampers and bypass)

Publications and Manuals
DescriptionPart NumberFile Size
Tech Guides
Technical Guide - Meridian Basic Control System 246923-YTG-A-0301 1559 KB PDF
Technical Guide - Meridian CV 271759-YTG-A-0301 1965 KB PDF
Technical Guide - Meridian EZ Zone Upgrade Guide 036-21423-001-A-0602 2993 KB PDF
Technical Guide - Meridian Plus 036-33061-001-A-0301 2423 KB PDF
Technical Guide - Meridian Prism Computer Front End Software Manual 036-33090-001-A-0802 1296 KB PDF
Technical Guide - Meridian Zoning 036-21478-001-A-0802 1674 KB PDF
Accessory Installation Instructions
Repair Part Installation Manual - Meridian 2ZMO004700224 & 2ZMO004700324 - Zone Manager For Basic Systems 035-22286-001-A-0909 42 KB PDF
Submittal Drawings
Submittal Data Sheet - Meridian 2ZML004703324 - MiniLink Communications - Interface 036-22281-001-A-0602 76 KB PDF
Submittal Data Sheet - Meridian Optional Components 036-22245-001-A-0602 1174 KB PDF
Submittal Data Sheet - Meridian Plus System Bill Of Materials 036-22306-001-A-0602 64 KB PDF
Submittal Data Sheet - CV - EX System Bill Of Materials 036-22280-001-A-0602 42 KB PDF
Submittal Data Sheet - CV-EX Worksheet 036-22282-001-A-0602 31 KB PDF
Submittal Data Sheet - Merdian 2ZRC0247000224 & 2ZRC0247000424 - CV Controller 036-22269-001-A-0602 90 KB PDF
Submittal Data Sheet - Merdian Basic System (Compliation of multiple individual) 036-22243-001-A-0602 2051 KB PDF
Submittal Data Sheet - Meridian 1ZRD00470XXXX - Rectangular Damper 036-22293-001-A-0602 96 KB PDF
Submittal Data Sheet - Meridian 2ZBD00470XXXX - Bypass Damper 036-22287-001-A-0602 102 KB PDF
Submittal Data Sheet - Meridian 2ZCO004705024 & 2ZCO004705124 - CO2 Sensor 036-22255-001-A-0602 239 KB PDF
Submittal Data Sheet - Meridian 2ZCP004703124 - CommLink II Communication Interface 036-22271-001-A-0602 63 KB PDF
Submittal Data Sheet - Meridian 2ZD0047000741 - Rectangular Bypass Damper Kit 036-22294-001-A-0602 55 KB PDF
Submittal Data Sheet - Meridian 2ZDA00470024 - Damper Actuator 036-22297-001-A-0602 68 KB PDF
Submittal Data Sheet - Meridian 2ZDK0047000739 - Rectangular Slaved - Zone Damper Kit 036-22296-001-A-0602 56 KB PDF
Submittal Data Sheet - Meridian 2ZDK0047000740 - Rectangular Zone Damper Kit 036-22295-001-A-0602 53 KB PDF
Submittal Data Sheet - Meridian 2ZDMD0047011XXXX - Pressure Independent - Zone Damper - Celsius 036-22291-001-A-0602 114 KB PDF
Submittal Data Sheet - Meridian 2ZDS004700124 & 2ZDS004700224 - 6" & 12" Duct Sensors 036-22275-001-A-0602 28 KB PDF
Submittal Data Sheet - Meridian 2ZEB00470124 - 8 Relay Staging Expansion Board 036-22308-001-A-0602 59 KB PDF
Submittal Data Sheet - Meridian 2ZEM004703424 - Remote Link 036-22252-001-A-0602 74 KB PDF
Submittal Data Sheet - Meridian 2ZGP004700124 & 2ZGP004700224 - General Purpose Controller 036-22264-001-A-0602 92 KB PDF
Submittal Data Sheet - Meridian 2ZLC004700124 - Lighting Panel Controller 036-22247-001-A-0602 86 KB PDF
Submittal Data Sheet - Meridian 2ZMD00470XXXX - Pressure Dependent - Zone Damper - Fahrenheit 036-22288-001-A-0602 103 KB PDF
Submittal Data Sheet - Meridian 2ZMD00471XXXX - Pressure Independent - Zone Damper - Fahrenheit 036-22290-001-A-0602 114 KB PDF
Submittal Data Sheet - Meridian 2ZMD00471XXXXX - Pressure Dependent - Zone Damper - Celsius 036-22289-001-A-0602 103 KB PDF
Submittal Data Sheet - Meridian 2ZMP004700124 & 2ZMP004700224 - Zone Manager - Plus System 036-22307-001-A-0602 182 KB PDF
Submittal Data Sheet - Meridian 2ZOH0047004524 - Wetbulb Module Controller - Celsius 036-22317-001-A-0602 91 KB PDF
Submittal Data Sheet - Meridian 2ZOH0047004524 - Wetbulb Module Controller - Fahrenheit 036-22246-001-A-0602 92 KB PDF
Submittal Data Sheet - Meridian 2ZOH004704524 - Outside Air Humidity Sensor 036-22253-001-A-0602 38 KB PDF
Submittal Data Sheet - Meridian 2ZOS004700124 - AZOSS Optimal Start Scheduler 036-22248-001-A-0602 92 KB PDF
Submittal Data Sheet - Meridian 2ZPS004704224 - Airflow Sensor for Pressure Independent Zone Control 036-22302-001-A-0602 32 KB PDF
Submittal Data Sheet - Meridian 2ZPS004704324 - Pressure Sensor 036-22301-001-A-0602 33 KB PDF
Submittal Data Sheet - Meridian 2ZRC004700524 & 2ZRC004700624 - CV - C Controller 036-22272-001-A-0602 77 KB PDF
Submittal Data Sheet - Meridian 2ZRE0047000024 - 4 Relay Output Expansion Board 036-22299-001-A-0602 59 KB PDF
Submittal Data Sheet - Meridian 2ZRE0047001024 & - 8 Relay Output Expansion Board 036-22273-001-A-0602 54 KB PDF
Submittal Data Sheet - Meridian 2ZRH004700223 - Return Air Humidity Sensor 036-22254-001-A-0602 35 KB PDF
Submittal Data Sheet - Meridian 2ZSA0047000024 MZ - SA - F Fahrenheit Stand Alone Damper Kit 036-22249-001-A-0602 102 KB PDF
Submittal Data Sheet - Meridian 2ZSA0047000124 MZ - SA - C Celsius Stand Alone Damper Kit 036-22250-001-A-0602 102 KB PDF
Submittal Data Sheet - Meridian 2ZSD00770XXXX - Slaved Zone Damper 036-22292-001-A-0602 103 KB PDF
Submittal Data Sheet - Meridian 2ZSM004702924 - System Manager System Interface 036-22270-001-A-0602 68 KB PDF
Submittal Data Sheet - Meridian 2ZSP0047000024 - Lighting Suppressor Kit Installation 036-22256-001-A-0602 76 KB PDF
Submittal Data Sheet - Meridian 2ZSP004704424 - Static Pressure Pickup Tube 036-22300-001-A-0602 25 KB PDF
Submittal Data Sheet - Meridian 2ZST0047000024 - Hand Held Service Tool 036-22251-001-A-0602 66 KB PDF
Submittal Data Sheet - Meridian 2ZTS00470424, 2ZTO004704024, 2ZTB004704123 - Room Sensors 036-22274-001-A-0602 53 KB PDF
Submittal Data Sheet - Meridian 2ZZC004700024 & 2ZZC004700124 - Zone Controller Board 036-22298-001-A-0602 96 KB PDF
Submittal Data Sheet - Meridian Basic - Zone Worksheet 036-22303-001-A-0602 32 KB PDF
Submittal Data Sheet - Meridian Basic Set-Up Information Sheet 036-22304-001-A-0602 22 KB PDF
Submittal Data Sheet - Meridian Basic System Bill Of Materials 036-22285-001-A-0602 63 KB PDF
Submittal Data Sheet - Meridian basic System Overview 036-22284-001-A-0602 214 KB PDF
Submittal Data Sheet - Meridian CS System 036-22241-001-A-0602 1622 KB PDF
Submittal Data Sheet - Meridian CV Set-Up Information Sheet 036-22278-001-A-0602 23 KB PDF
Submittal Data Sheet - Meridian CV System Bill Of Materials 036-22268-001-A-0602 42 KB PDF
Submittal Data Sheet - Meridian CV System Overview 036-22267-001-A-0602 150 KB PDF
Submittal Data Sheet - Meridian CV Worksheet 036-22277-001-A-0602 31 KB PDF
Submittal Data Sheet - Meridian CV-EX Set-Up Information Sheet 036-22283-001-A-0602 23 KB PDF
Submittal Data Sheet - Meridian CV-EX System (Compliation of multiple individual Submittal Data Sheets) 036-22242-001-A-0602 1395 KB PDF
Submittal Data Sheet - Meridian CV-EX System Overview 036-22279-001-A-0602 212 KB PDF
Submittal Data Sheet - Meridian OE250Y - Outside Air Temperature Sensor 036-22276-001-A-0602 40 KB PDF
Submittal Data Sheet - Meridian Plus Set-Up Information Sheet 036-22311-001-A-0602 24 KB PDF
Submittal Data Sheet - Meridian Plus System 036-22244-001-A-0602 3258 KB PDF
Submittal Data Sheet - Meridian Plus System Overview 036-22305-001-A-0602 550 KB PDF
Submittal Data Sheet - Meridian Plus Worksheet - Constant Volume Units 036-22310-001-A-0602 29 KB PDF
Submittal Data Sheet - Meridian Plus Worksheet - Zoned Units 036-22309-001-A-0602 32 KB PDF
Wiring Diagrams
Wiring Diagram - Meridian Basic System 035-18964-000-A-0602 392 KB PDF
Wiring Diagram - Meridian Basic System Page 1 035-18965-000-A-0602 93 KB PDF
Wiring Diagram - Meridian Basic System Page 2 035-18966-000-A-0602 66 KB PDF
Wiring Diagram - Meridian Basic System Page 3 035-18967-000-A-0602 49 KB PDF
Wiring Diagram - Meridian Basic System Page 4 035-18968-000-A-0602 53 KB PDF
Wiring Diagram - Meridian Basic System Page 5 035-18969-000-A-0602 55 KB PDF
Wiring Diagram - Meridian Basic System Page 6 035-18970-000-A-0602 73 KB PDF
Wiring Diagram - Meridian CV System Wiring Diagram Package 035-18953-000-A-0602 368 KB PDF
Wiring Diagram - Meridian CV System Wiring Diagram Page 1 035-18954-000-A-0602 142 KB PDF
Wiring Diagram - Meridian CV System Wiring Diagram Page 2 035-18955-000-A-0602 93 KB PDF
Wiring Diagram - Meridian CV System Wiring Diagram Page 3 035-18956-000-A-0602 49 KB PDF
Wiring Diagram - Meridian CV System Wiring Diagram Page 4 035-18957-000-A-0602 73 KB PDF
Wiring Diagram - Meridian CV-EX System Manager Wiring Diagram Package 035-18958-000-A-0602 587 KB PDF
Wiring Diagram - Meridian CV-EX System Manager Wiring Diagram Page 1 035-18959-000-A-0602 314 KB PDF
Wiring Diagram - Meridian CV-EX System Manager Wiring Diagram Page 2 035-18960-000-A-0602 93 KB PDF
Wiring Diagram - Meridian CV-EX System Manager Wiring Diagram Page 3 035-18961-000-A-0602 49 KB PDF
Wiring Diagram - Meridian CV-EX System Manager Wiring Diagram Page 4 035-18962-000-A-0602 51 KB PDF
Wiring Diagram - Meridian CV-EX System Manager Wiring Diagram Page 5 035-18963-000-A-0602 73 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Package 035-18971-000-A-0602 699 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Package Page 8 035-18979-000-A-0602 55 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Page 1 035-18972-000-A-0602 209 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Page 2 035-18973-000-A-0602 93 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Page 3 035-18974-000-A-0602 73 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Page 4 035-18975-000-A-0602 49 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Page 5 035-18976-000-A-0602 51 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Page 6 035-18977-000-A-0602 49 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Page 7 035-18978-000-A-0602 52 KB PDF
Wiring Diagram - Meridian Plus System Wiring Diagram Page 9 035-18980-000-A-0602 73 KB PDF
Wiring Diagram - Meridian System Component Wiring Diagrams Master Release 035-18352-001-A-0602 2955 KB PDF
Furnace Air Conditioning Heat Pumps Packaged System Air Handlers Evaporator Coil Indoor Air Quality Furnace Air Conditioning Heat Pumps Packaged System Air Handlers Evaporator Coil Indoor Air Quality




Find a York Distributor
NATE
Source 1


Copyright © 2001-2009 Johnson Controls  All Rights Reserved.